Reliance Electric 50V4060 50 HP (37 kW), 380–460 VAC, 3‑phase AC drive
May 30, 2026

Reliance Electric 50V4060 50 HP (37 kW), 380–460 VAC, 3‑phase AC drive

Reliance Electric 50V4060 is a 50 HP (37 kW), 380–460 VAC, 3‑phase AC drive from the GV3000/SE series, supporting both V/Hz and vector control for high‑performance motor control.

Description

Product Introduction

Reliance Electric 50V4060 is a 50 HP (37 kW), 380–460 VAC, 3‑phase AC drive from the GV3000/SE series, supporting both V/Hz and vector control for high‑performance motor control.

Model Interpretation

  • 50 = 50 HP

  • V = GV3000/SE series

  • 40 = 460 VAC input

  • 60 = Standard firmware, NEMA 1 enclosure

Technical Parameters

  • Power: 50 HP / 37 kW

  • Input: 380–460 VAC, 3‑phase, 50/60 Hz

  • Output current: ~67 A continuous

  • Input current: ~72 A

  • Max output frequency: 200 Hz

  • Control modes: V/Hz, sensorless vector, closed‑loop vector

  • Enclosure: NEMA 1 (IP20)

  • Protection: Overcurrent (200%), overload (150%/1 min), short‑circuit, ground fault

  • Operating temp: 0 °C to +45 °C

  • Status: Discontinued; available as surplus/refurbished

Interface & Communication

  • Power terminals: 3‑phase AC in, 3‑phase AC out

  • Control terminals: Start/stop, speed reference, fault reset, encoder feedback

  • Front panel: Built‑in keypad & LED display for setup/monitoring

  • Options: RS‑232/485, Profibus, DeviceNet communication modules

Core Functions

  • Precision speed/torque control: Closed‑loop vector with encoder feedback

  • Auto‑tuning: Automatic motor parameter identification

  • Speed range: 1:600 (with 1024 PPR encoder)

  • Dynamic response: 15 Hz typical bandwidth

  • Fault diagnostics: Built‑in fault logging & parameter monitoring

Application Scenarios

  • Industrial motion control: Conveyors, extruders, machine tools

  • Material handling: Cranes, hoists, palletizers

  • Process industry: Pumps, fans, mixers requiring variable speed

  • Retrofits: Replacement for legacy Reliance GV3000 installations

Operation & Maintenance

  • Mount in NEMA 1 enclosure, well‑ventilated, avoid vibration

  • Wire per schematic: AC line, motor, control signals, encoder

  • Set motor nameplate data, speed/ current limits via keypad

  • Regularly inspect fans, heat sinks, connections; keep clean

  • Discontinued; use refurbished units or upgrade to modern AC drives


Get a Quote