Bosch Rexroth DDS2.1-W025-DA01 Digital Servo Drive
Description
Model Definition
DDS2.1: Servo drive series for DIAX02 system
W: Internal cabinet convection air cooling
025: 25 A continuous rated current, 50 A short-term peak current
DA01: Analog communication interface + standard firmware version
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15%, powered by TVD/TVM power units
Control power supply: 24 V DC (20–28 V DC)
Continuous output current: 25 A
Peak output current: 50 A (short-term)
Current loop cycle: 125 μs
Speed loop cycle: 500 μs
Position loop cycle: 2 ms
Power dissipation: ~110 W
Compatible motors: MDD/MKD synchronous servo motors, LAR/LAF linear motors, 2AD series motors
Mechanical & Environmental Parameters
Cooling method: Internal cabinet convection air cooling
Protection class: IP20 (front panel), IP10 (whole unit)
Operating temperature: 0 °C to +45 °C (20% derating at 55 °C)
Storage temperature: -30 °C to +85 °C
Max installation altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 interface (digital encoder compatible)
System bus: Shared 300 V DC bus for multi-axis parallel connection
Communication: DA01 analog module (±10 V speed/torque command)
Digital I/O: 6 isolated inputs, 3 isolated outputs
Service port: RS232 (IndraWorks parameter setting/diagnosis)
Expansion slots: U1–U5 for fieldbus/I/O modules
Core Functions
Three-loop control (current/speed/position) for precise motion
Analog command interface (DA01) for legacy system integration
Compact internal cooling for narrow cabinet installation
Comprehensive protection: overvoltage/undervoltage/overcurrent/short-circuit/overheating
Supports torque/speed/position control modes
Modular design for easy maintenance and expansion
Application Scenarios
CNC machine tool auxiliary axes
Printing/textile/packaging machinery (analog control)
Small automated assembly/conveying lines
DIAX02 system upgrades with analog requirements
General automation with limited cabinet space
Usage and Maintenance
Ensure unobstructed cabinet airflow for cooling efficiency
Keep ambient temperature ≤45 °C to avoid performance loss
Complete power/feedback/control wiring before power-on
Set parameters via IndraWorks per motor/load conditions
Clean heat sinks/air passages every 6 months; inspect terminals
Calibrate control loops/feedback signals annually