Bosch Rexroth DDS2.1-W015-DA01 Digital Servo Drive
Description
Model Definition
DDS2.1: DIAX02 drive series (firmware v2.x)
W: Internal cabinet air cooling (convection, no external fan)
015: 15 A continuous, 30 A peak current
DA01: Digital servo feedback + Analog interface (±10 V command) + incremental encoder emulation
‑00/‑01: Revision/firmware variant (often omitted in short notation)
Technical Specifications
Electrical
DC bus: 300 V DC ±15% (from TVD/TVM power supplies)
Control supply: 24 V DC (20–28 V DC)
Continuous current: 15 A
Peak current: 30 A (short‑term)
Current loop: 125 μs
Speed loop: 500 μs
Position loop: 2 ms
Power dissipation: ~100 W (@15 A)
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal cabinet airflow (W‑type, convection)
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 (DSF digital servo encoder, dual‑channel)
Command interface: DA01 analog (±10 V speed/torque command, incremental encoder emulation for host)
System bus: Shared 300 V DC bus for multi‑axis parallel operation
Digital I/O: 6 isolated inputs / 3 isolated outputs (base unit)
Service port: RS232 (IndraWorks setup/diagnostics)
Expansion slots: U1–U5 (for fieldbus/SERCOS modules, optional)
Core Functions
Three‑loop control (current/speed/position) for precision motion
W‑type internal convection cooling for space‑saving cabinet mounting
DA01 analog + DSF digital feedback combo: analog command, digital feedback
Incremental encoder emulation for compatibility with analog‑only controllers
Comprehensive protection: over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque/speed/position control modes
Application Scenarios
Low‑power CNC auxiliary axes (analog command from CNC)
Light‑duty textile, printing, packaging machinery (±10 V control)
Small assembly lines and material handling with analog PLCs
DIAX02 system upgrades needing 15 A + analog interface
Cabinet‑space constrained machines with internal cooling
Usage and Maintenance
Ensure cabinet airflow ≥ 500 m³/h for internal cooling
Keep ambient ≤45 °C to avoid derating
Wire power, feedback (X4), analog command, and I/O before power‑on
Configure via IndraWorks: match motor, set DA01 analog scaling
Clean heatsink/air passages every 6 months; inspect terminals
Calibrate control loops/feedback annually
Get a Quote