Bosch Rexroth DDS2.1‑W (DDS02.1‑W) Series Digital Servo Drive
Description
Model Definition (Core “W” Meaning)
DDS2.1: DIAX02 drive platform, firmware version 2.x
W: Internal cabinet air cooling (heat dissipated inside the control cabinet via convection/ventilation; compact, no external fan)
###: 2‑digit continuous current rating (e.g., 050=50 A, 100=100 A, 150=150 A, 200=200 A)
‑D/‑DSxx: Feedback/communication options (e.g., D=DSF digital feedback; DS04=SERCOS interface)
Technical Specifications (W‑Series Base)
Electrical
DC bus: 300 V DC ±15% (from TVD/TVM power supplies)
Control supply: 24 V DC (20–28 V DC, ~1.1 A consumption)
Continuous current: 15 / 50 / 100 / 150 / 200 A
Peak current: 2× continuous (short‑term, e.g., 100 A cont. → 200 A peak)
Control loops: Current (125 μs), Speed (500 μs), Position (2 ms)
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal cabinet airflow (W‑type) (no external blower; relies on cabinet ventilation)
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~7.5 kg (lighter than A‑type external cooling)
Interface and Communication Configuration
Motor feedback: X4 (DSF digital servo feedback standard; optional RSF resolver)
System bus: Shared 300 V DC bus for multi‑axis parallel operation
Communication: Modular slots U1–U5 (SERCOS DS04/DS54, analog, or fieldbus cards)
Digital I/O: 6 isolated inputs / 3 isolated outputs (expandable via modules)
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
Three‑loop precision control (current/speed/position)
Compact internal cooling (W‑type) for space‑saving cabinet installation
Modular feedback/communication expansion for flexible system integration
Comprehensive protection: Over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque/speed/position control modes
DIAX02 firmware compatible (FW module ordered separately)
Application Scenarios
Medium‑power CNC axes (milling/turning machines)
Multi‑axis textile, printing, and packaging machinery
Assembly lines and material handling robots
Space‑constrained control cabinets (no external blower needed)
DIAX02 system upgrades with internal cooling
W‑Type vs. A‑Type Cooling (Key Difference)
Type Cooling Method Weight Best For
W Internal cabinet air (convection) ~7.5 kg Compact cabinets, medium power (≤150 A)
A External blower (cabinet exhaust) ~11 kg High power (150–200 A), heavy‑duty continuous operation
Usage and Maintenance
Ensure cabinet airflow ≥ 350 m³/h for internal cooling
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/control wiring before power‑on
Configure via IndraWorks (match motor/load parameters)
Clean heatsink/air passages every 6 months; inspect terminals
Calibrate control loops/feedback annually
Get a Quote