Bosch Rexroth DDS03.2-W050-B Digital Servo Drive
Description
Model Definition
DDS03.2: DIAX03 system servo drive series (firmware v3.x)
W: Internal cabinet air cooling
050: 50 A continuous current, 100 A peak current
B: Basic drive unit (no pre-configured BE/BS interface card; expansion slots available)
(suffix omitted): Hardware revision not specified (standard 01 or 02)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM supplies)
Control supply: 24 V DC (20–28 V DC)
Continuous output current: 50 A
Peak output current: 100 A (short-term)
Current loop: 125 μs
Speed loop: 500 μs
Position loop: 2 ms
Power dissipation: ~200 W (@50 A)
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series, LSF/ADF motors
Mechanical & Environmental
Cooling: Internal air blower + heatsink
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 80 mm × 408 mm × 180 mm
Weight: ~6.2 kg
Interface and Communication Configuration
Motor feedback: X4 interface (digital encoder + resolver, dual-channel)
System bus: Shared 300 V DC bus for multi-axis parallel connection
Communication: B-type base unit (U1 slot for optional comms card: SERCOS/analog/PROFIBUS; U5 for firmware; U2–U4 for I/O/options)
Digital I/O: 6 isolated inputs / 3 isolated outputs (basic configuration)
Service port: RS232 (IndraWorks setup/diagnostics)
Core Functions
Three-loop control (current/speed/position) for high precision
B-type flexibility: Customizable via plug-in cards (SERCOS, analog, safety I/O)
Internal cooling saves cabinet space for dense multi-axis layouts
Comprehensive protection: over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque/speed/position control modes
Modular design for easy maintenance/upgrades
Application Scenarios
High-power CNC machine axes (50 A continuous current demand)
Textile/printing/packaging machinery (heavy-load multi-axis sync)
Automated assembly lines & handling robots (high-torque applications)
Automation systems requiring custom interface expansion (SERCOS/analog/safety)
DIAX03 system upgrades with scalable high-power servo control
Usage and Maintenance
Ensure unobstructed cabinet airflow (maintain cooling efficiency for 50 A operation)
Keep ambient ≤45 °C to avoid performance derating
Complete power/feedback/control wiring before power-on
Configure via IndraWorks (match motor/load parameters; install optional comms/safety cards first)
Clean air passages/heatsinks every 6 months; inspect terminals
Calibrate control loops/feedback annually for stability