Bosch Rexroth DDS03.2-W030-B12-01-FW Digital Servo Drive
Description
Model Definition
DDS03.2: DIAX03 system servo drive series (firmware v3.x)
W: Internal cabinet air cooling
030: 30 A continuous current, 60 A peak current
B12: Basic unit with function ID 12 (SERCOS interface, DSS02.1M card)
01: Hardware revision 01
FW: Factory-integrated firmware module (DSM02.3-FW)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM supplies)
Control supply: 24 V DC (20–28 V DC)
Continuous output current: 30 A
Peak output current: 60 A (short-term)
Current loop: 125 μs
Speed loop: 500 μs
Position loop: 2 ms
Power dissipation: ~120 W (@30 A)
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal air blower + heatsink
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 interface (digital servo encoder + resolver)
System bus: Shared 300 V DC bus for multi-axis connection
Communication: B12 with SERCOS (DSS02.1M in U1 slot)
Digital I/O: 6 inputs / 3 outputs (isolated)
Service port: RS232 (IndraWorks setup)
Firmware: U5 slot with DSM02.3-FW (FWA-DIAX03-SSE-02VRS)
Core Functions
Three-loop control (current/speed/position)
Pre-loaded firmware enables plug-and-play deployment
SERCOS interface for high-speed multi-axis synchronization
Comprehensive protection: over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque/speed/position control modes
Modular design for easy maintenance and upgrade
Application Scenarios
Medium-power CNC machine axes
Textile, printing, packaging machinery
Multi-axis handling robots and assembly lines
Automation requiring SERCOS real-time communication
DIAX03 system upgrades with pre-configured firmware
Usage and Maintenance
Ensure unobstructed cabinet airflow
Keep ambient temperature ≤45 °C
Complete wiring before power-on
Configure via IndraWorks
Clean air ducts/heatsinks every 6 months
Calibrate loops annually
Get a Quote