Bosch Rexroth DDS02.1-W025-DA01-01 Digital Servo Drive
Description
Model Definition
DDS02.1: DIAX02 system servo drive series 02.1
W: Cabinet internal air cooling
025: 25 A continuous rated current
DA01: Analog interface + digital servo feedback (DSF)
01: Hardware version 01
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (from TVD/TVM power supplies)
Control power: 24 V DC (20–28 V DC)
Continuous output current: 25 A
Peak output current: 50 A (short-term)
Current loop cycle: 62.5 μs
Speed loop cycle: 250 μs
Position loop cycle: 1 ms
Feedback: High-resolution DSF digital servo feedback
Power dissipation: ~80 W
Mechanical & Environmental Parameters
Cooling: Cabinet internal air cooling (vertical mounting required)
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (derate to 55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (derate above)
Weight: ~8 kg
Dimensions (W×H×D): 110 mm × 390 mm × 310 mm
Interface and Communication Configuration
Control interface: Analog (±10 V) for torque/speed/position control
Motor feedback: DSF digital servo feedback
System bus: Shared 300 V DC bus for multi-axis
Digital I/O: 8 inputs / 4 outputs (enable, fault, limits, brake)
Expansion: Slots for communication/functional modules
Service port: RS232 (IndraWorks for parameterization)
Core Functions
Current/speed/position three-loop control for high dynamic response
Analog interface enables seamless connection to legacy controllers
DSF feedback ensures high positioning accuracy and noise immunity
Modular design for flexible expansion and easy maintenance
Comprehensive protection: Overvoltage, undervoltage, overcurrent, short circuit, overheating, feedback loss
Supports torque, speed, position control modes
Application Scenarios
Medium-sized CNC machine tools
Printing, textile, packaging machinery
Light-duty multi-axis synchronous lines
Robotics and material handling
Retrofits for analog-controlled automation systems
Usage and Maintenance
Install vertically with adequate cabinet ventilation
Operate within 0–45 °C ambient temperature
Complete DC bus, control power, motor/feedback cabling before commissioning
Configure parameters via IndraWorks
Clean fan/heat sink every 6 months; inspect terminals regularly
Calibrate control loops every 2 years
Get a Quote