Bosch Rexroth DDS02.1-A100-DL41-01 Digital Servo Drive
Description
Model Definition
DDS02.1: DIAX02 system servo drive series, version 02.1
A: External air cooling
100: 100 A continuous rated current
DL41: PROFIBUS DP communication interface with standard digital feedback function
01: Hardware version 01
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15%, supplied by TVD / TVM power supply unit
Control power supply: 24 V DC (20 V DC to 28 V DC)
Continuous output current: 100 A
Peak output current: 200 A (short-time operation)
Current loop cycle: 62.5 μs
Speed loop cycle: 250 μs
Standard feedback: DSF digital servo feedback
Mechanical & Environmental Parameters
Cooling method: External air cooling
Protection class: IP20
Operating temperature: 0 °C to +45 °C, derating allowed up to 55 °C
Storage temperature: -30 °C to +85 °C
Approximate weight: 16 kg
Interface and Communication Configuration
Control interface: PROFIBUS DP fieldbus
Motor feedback interface: DSF digital servo feedback
System bus: Shared 300 V DC bus for multi-axis connection
Digital I/O: Enable, fault alarm, limit switch signals
Expansion slots: Support additional communication and functional modules
Core Functions
Three-loop closed-loop control including current loop, speed loop and position loop, delivering fast dynamic response and high positioning accuracy.
Stable data transmission and reliable multi-axis linkage via PROFIBUS DP bus.
Modular structure allows flexible expansion of functions and interfaces according to on-site demands.
Comprehensive protection functions against overvoltage, undervoltage, overcurrent, overheating and wire breakage.
Supports torque, speed and position control modes for diverse motion requirements.
Application Scenarios
Heavy-duty CNC machine tools, gantry machines and large lathes
Multi-axis synchronous production lines, industrial robots and injection molding machines
High-load test benches and dynamic simulation equipment
Metallurgical tension control and large-scale printing & packaging machinery
Usage and Maintenance
Install the drive vertically and ensure unobstructed external cooling air duct.
Keep ambient temperature below 45 °C and altitude within 1000 meters during operation.
Complete wiring of DC bus, control power, motor feedback and fieldbus before commissioning, and configure parameters via IndraWorks software.
Clean dust and inspect terminal connections every 6 months. Calibrate control loops once per year for stable operation.
Get a Quote