Leistec DDS02.1-A050-DA01-01 Digital Servo Drive
Description
Model Explanation
DDS02.1: DIAX02 system, driver series 02.1
A: External air cooling (heat sink outside the cabinet)
050: Rated continuous current 50 A
DA01: Analog interface + incremental encoder simulation (slot U1)
01: Hardware version number
Technical Parameters Electrical specifications
DC bus: 300 V DC ±15% (powered by TVD/TVM power supply)
Control power supply: 24 V DC (20–28 V)
Continuous current: 50 A
Peak current: 100 A (short-term)
Control cycle: Current loop ≈ 62.5 μs, Speed loop ≈ 250 μs
Mechanical and environmental
Cooling method: External air cooling (A)
Protection level: IP20
Operating temperature: 0 to +45 ℃ (55 ℃ is within the tolerance range)
Storage temperature: -30 to +85 ℃
Weight: Approximately 11 kg
Interface and communication configuration
Control interface: Analog ±10 V (speed/position command)
Feedback interface: DSF digital servo feedback (standard)
Encoder simulation: Incremental A/B/Z signal output
I/O: Digital input/output, enable, alarm, limit
Bus expansion: Plug-in SERCOS, PROFIBUS, etc. communication cards Core function
Full closed-loop control: three loops of current / speed / position, with fast dynamic response
Simulation + encoder simulation: compatible with traditional analog controllers
Modular expansion: communication card and feedback card are plug-and-play
Complete protection: overvoltage, undervoltage, short circuit, overheating, open circuit protection
Firmware independence: U5 slot inserts firmware module, facilitating replacement and upgrade Applicable scenarios
Machinery: Small and medium-sized CNC machines, machining centers, lathes
Automation: Textile machinery, printing and packaging equipment, injection molding machines
Testing: Medium and low-load fatigue tests, motion simulation platforms
Logistics: Robots, gantry frames, synchronous lifting axes Use and Maintenance
Installation: Vertical installation, with unobstructed external air duct and away from heat sources
Heat dissipation: Ambient temperature ≤ 45 ℃, altitude ≤ 1000 m
Commissioning: 300 V DC, 24 V DC, motor feedback, analog instructions; Parametric settings in IndraWorks software
Maintenance: Clean and inspect terminals every 6 months; Calibrate current loop and position loop annually