Leistritz DDS02.1 - A/W100 Digital Servo Drive
Description
Model Explanation
DDS02.1: Series (2nd generation, version 1)
A: External air cooling (cooling from the outside of the cabinet)
W: Internal air cooling (internal fan circulation)
100: Rated continuous current 100 A
Complete model example: DDS02.1-A100-DA01-01-FW
DA01: Analog interface + incremental encoder simulation
01: Hardware version
FW: Includes firmware module
Technical Parameters
Electrical Parameters
DC bus voltage: 300 V DC ±15%
Rated continuous current: 100 A
Peak current: 200 A (short time)
Control mode: Current / Speed / Position closed loop
Feedback: DSF digital servo feedback (standard)
Mechanical and Environmental
Cooling method: A = External air cooling; W = Internal air cooling
Protection level: IP20
Operating temperature: 0 to +45 ℃ (reduction capacity up to 55 ℃)
Storage temperature: -30 to +85 ℃
Weight: Type A about 11 kg; Type W about 7.5 kg
Interface and Communication Configuration
Control interface: Analog (±10 V), SERCOS, PROFIBUS (optional)
Feedback interface: DSF digital servo, incremental encoder
Bus: Shared 300 V DC bus (with TVD/TVM power supply)
I/O: Digital input/output, enable, alarm, limit position Core function
High-power drive: 100 A continuous current, suitable for heavy-duty motors
Full closed-loop control: current loop, speed loop, position loop, with fast dynamic response
Modular design: Communication / Feedback / Function cards are plug-and-play, flexible configuration
Overload protection: Overcurrent, overvoltage, overheat, stall, grounding fault protection
Firmware upgradeable: Independent firmware module, supports function updates Applicable scenarios
Machine tools: Large CNC, gantry milling machines, heavy-duty lathes
Automation: Injection molding machines, presses, die-casting machines
Testing: High-load fatigue test benches, vibration tables
Metal processing: Rolling mills, tension control, AGC roll gap control Use and Maintenance
Installation: Vertical installation. Type A requires an external air duct. Type W has internal ventilation of ≥ 300 m³/h.
Heat dissipation: Ambient temperature ≤ 45 ℃, altitude ≤ 1000 m.
Commissioning: Connect DC 300 V, motor feedback, control signal; parameterize using IndraWorks software.
Maintenance: Clean and inspect wiring every 6 months; calibrate current loop and position loop annually.
Get a Quote