JANCD-CU20
Description
1. Product Overview
2. Technical Specifications
2.1 Electrical
Operating Voltage: 24 V DC ±10%
Power Consumption: ≈ 10 W
Isolation: Opto‑isolated digital I/O (500 Vrms for 1 minute)
2.2 I/O Configuration
Inputs: 16 channels, 24 V DC, sink/source selectable, 10 mA/channel
Outputs: 16 channels, 24 V DC, 0.5 A/channel, short‑circuit protected
Inputs: 4 channels, 0–10 V DC / 4–20 mA, 12‑bit resolution
Outputs: 2 channels, 0–10 V DC / 4–20 mA, 12‑bit resolution
2.3 Physical
Dimensions: 180 mm × 120 mm × 30 mm
Weight: ≈ 0.8 kg
Mounting: Standard 3U slot in XRC controller chassis
2.4 Environmental
Operating Temperature: 0 °C to +40 °C (non‑condensing)
Storage Temperature: −20 °C to +60 °C
Humidity: 30%–80% RH (non‑condensing)
Vibration: ≤0.5 G (10–500 Hz)
Altitude: ≤1,000 m (no derating)
2.5 Compliance
CE (EN 61131‑2), UL 508, CSA C22.2 No. 142
3. Compatibility
Controller: Motoman XRC / XR‑C (all firmware versions v3.x–v5.x)
Compatible Boards: JANCD‑CU02 / CU05 / CU06 / CU07 (same form factor & bus interface)
Replacement: Direct replacement for older JANCD‑CU02/CU05 I/O boards
4. Interface Connectors
CN1: 24 V DC power input (2‑pin)
CN2: Digital I/O terminal block (34‑pin)
CN3: Analog I/O terminal block (12‑pin)
CN4: System bus (to CPU board JANCD‑CU06, 40‑pin)
CN5: Shield & ground connection
5. Key Features
High‑Speed Signal Processing: Fast response for real‑time robot control
Noise Immunity: Opto‑isolation and EMC filtering for harsh industrial environments
Easy Configuration: I/O mapping via teach pendant or XRC software
Hot‑Swap Support: Replaceable without system shutdown (in redundant setups)
Diagnostic LEDs: Power, communication, and I/O status indicators
6. Applications
Welding Robots: Arc start/stop, gas control, wire feed speed analog output
Material Handling: Conveyor control, sensor input, gripper actuation
Painting Robots: Analog flow control, spray gun on/off, safety interlocks
Assembly Lines: PLC intercommunication, tool change signals, quality sensors
7. Installation & Maintenance
Power OFF the XRC controller and lockout/tagout.
Remove the controller’s front cover.
Insert JANCD‑CU20 into an empty 3U slot; secure with two screws (0.6–0.8 N·m).
Connect CN1–CN5 cables; ensure tight, secure connections.
Power ON; run I/O self‑diagnosis via the teach pendant to verify operation.
8. Troubleshooting (XRC Fault Codes)
E21: I/O board power failure → Check 24 V DC supply and CN1 wiring.
E22: I/O communication error → Verify CN4 bus cable and CPU board.
E23: Digital input short circuit → Inspect field wiring and sensors.
E24: Analog output overload → Check load impedance and wiring.
9. Commercial Information
New Original Price: USD 1,200–1,600
Refurbished Price: USD 500–800
Warranty: 12 months (new), 6 months (refurbished)
Get a Quote