JANCD‑CP01B (Yaskawa YASNAC)
Description
1. Basic Product Information
Brand & Model: Yaskawa Electric, JANCD‑CP01B (JANCDCP01B, DE8401365‑E1)
Product Type: CNC Control Card / I/O Interface / CPU Expansion Module
Compatible Systems: YASNAC M‑II, XRC, PC NC, LX3; also used in Motoman robot controllers
Backplane: Mounts on JZNC‑RK22 backplane
Power Input: 24V DC (±10%)
PCB Structure: 4‑layer industrial‑grade PCB
Weight: Approx. 1.59 kg (3.5 lb) (standard) / 0.5 kg (compact variant)
Dimensions: ~161 × 110 mm (6.35 × 4.33 in)
Status: Discontinued (available as new/refurbished industrial spare)
2. Core Functions & Technical Features
Primary Functions
Enhanced CNC Control Logic: Faster processing for motion control, I/O logic, and system coordination vs. JANCD‑CP01.
I/O Hub: Manages digital/analog I/O between main CPU, operator panels, servo drives, and peripherals.
Communication Bridge: Supports RS‑232, parallel bus, and optional Modbus RTU/RS‑485.
Status & Fault Monitoring: On‑board LEDs for power, run, fault, and communication status.
System Protection: Overcurrent, overvoltage, undervoltage, thermal, and ESD protection.
Key Technical Characteristics
Industrial‑grade for harsh factory environments (dust, vibration, temperature).
Low power consumption (max 500 mA).
Direct plug‑and‑play replacement for JANCD‑CP01 and legacy CP‑series boards.
Stable long‑term operation for legacy CNC/robot systems.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Operating Voltage | 24V DC ±10% |
| Max Current | 500 mA |
| Operating Temp | 0°C to 55°C |
| Storage Temp | -20°C to 85°C |
| Communication | RS‑232, Parallel Bus; optional Modbus RTU/RS‑485 |
| PCB Layers | 4‑layer |
| Weight | 1.59 kg (standard) / 0.5 kg (compact) |
| Dimensions | ~161 × 110 mm |
4. Typical Applications
Legacy YASNAC CNC machines (milling, lathe, grinding, machining centers).
Yaskawa Motoman robot controllers (DX100, XRC).
Retrofit/maintenance of aging Yaskawa CNC/robot systems (direct upgrade for JANCD‑CP01).
5. Safety & Installation Notes
Power Safety: Disconnect main power; wait ≥5 minutes for residual voltage discharge.
Grounding: Ensure system grounding ≤100 Ω for EMC/safety.
ESD Protection: Use anti‑static wrist straps/mats during handling.
Mounting: Securely install on JZNC‑RK22 backplane; fully seat all connectors.
Thermal Management: Maintain ventilation; avoid high‑heat components.
6. Availability & Support
Condition: New, refurbished, or used (industrial spares).
Warranty: Typically 90–365 days; 24 months for refurbished units.
Support: Limited manufacturer support; third‑party repair/refurbishment available.
Get a Quote