JZNC-IOP32E (Yaskawa CNC Digital I/O Module)
May 29, 2026

JZNC-IOP32E (Yaskawa CNC Digital I/O Module)

JZNC-IOP32E (often miswritten as J2NC-IOP32E) is a dedicated 32-point digital input/output expansion module for Yaskawa YASNAC i80 CNC systems. It acts as an interface between the main CNC controller and on-site machine peripherals, delivering stable signal transmission and reliable electrical isolation for industrial machine tools.

Description

Model Definition

  • Model: JZNC-IOP32E

  • Manufacturer: Yaskawa Electric

  • Series: YASNAC i80 legacy CNC control system

  • Type: Digital I/O expansion board

Technical Specifications

Electrical Parameters

  • Operating voltage: 24 VDC ±10%

  • Digital inputs: 16 points (24 VDC)

  • Digital outputs: 16 points

  • Output type: Relay or transistor

    • Relay output: Max 2 A per channel at 250 VAC

    • Transistor output: Max 0.5 A per channel at 24 VDC

  • Isolation: Optocoupler isolation between internal circuits and field signals

  • Power consumption: Approximately 5 W

Mechanical & Environmental Parameters

  • Installation: Slot-mounted PCB for standard i80 rack

  • Dimensions (W×H×D): 220 mm × 150 mm × 20 mm

  • Weight: Approximately 0.4 kg

  • Operating temperature: 0 °C to +50 °C

  • Operating humidity: 10% – 85% RH, non-condensing

Core Functions

  • Collect digital signals from limit switches, proximity sensors and control buttons on machine tools.

  • Drive external actuators such as relays, solenoid valves and indicator lights.

  • Expand total I/O capacity of YASNAC i80 CNC system for tool magazines, fixtures and cooling units.

  • Provide optoelectronic isolation to prevent interference and protect the main controller.

  • Realize signal interaction between CNC host and auxiliary automation equipment.

Application Scenarios

  • Yaskawa YASNAC i80 series CNC machine tools and control cabinets.

  • Lathes, milling machines and machining centers requiring I/O expansion.

  • Retrofit, maintenance and spare parts replacement for legacy Yaskawa CNC systems.

Maintenance Notes

  • Cut off all power supply before installation, removal or wiring.

  • Keep the module dry and dust-free to avoid poor contact or circuit damage.

  • Regularly check terminal connections and board seating.

  • Use only the original or fully compatible replacement module to ensure system stability.