Yaskawa DF9200676-D0N I/O Control Board (JANCD-MRY01B-1)
May 29, 2026

Yaskawa DF9200676-D0N I/O Control Board (JANCD-MRY01B-1)

The DF9200676-D0N is the RoHS-compliant, lead-free version of DF9200676-D0, a digital I/O board for Yaskawa Motoman MRC/XRC robot controllers. It shares the same form, fit, and function as D0, but with environmentally friendly components and updated manufacturing processes.

Description

Model Definition

  • DF9200676: Base I/O board part number

  • D0N: D0 revision + N (RoHS/lead-free)

  • JANCD-MRY01B-1: Yaskawa official model name

  • Difference from D0: D0 = standard; D0N = RoHS lead-free (pin-to-pin compatible)

Specifications

Electrical

  • Input Voltage: 24 V DC ±10%

  • I/O Channels: 16 digital inputs / 16 digital outputs

  • Signal Level: 24 V DC / TTL compatible

  • Isolation: Optocoupler isolation per channel

  • Power Consumption: ~18 W

  • Features: Surge suppression, short-circuit protection, RoHS compliance

Mechanical & Environmental

  • Dimensions: 220 × 150 × 25 mm

  • Weight: ~0.48 kg

  • Operating Temp: 0 °C to 55 °C

  • Storage Temp: −20 °C to 70 °C

  • Humidity: ≤80% RH (non-condensing)

  • Protection: IP20 (cabinet use)

  • Compliance: RoHS, CE

Interfaces

  • CN1: 24 V DC power input

  • CN2–CN3: 16-in / 16-out I/O terminals

  • CN4: System bus (to main backplane)

  • Onboard LEDs: PWR, RUN, ALM, CH status

Core Functions

  1. Digital I/O Control: 16 inputs (sensors, switches) / 16 outputs (relays, actuators).

  2. Signal Conditioning: Filtering, isolation, level conversion for external signals.

  3. Bus Communication: High-speed data exchange with main controller via backplane.

  4. Fault Monitoring: Channel-level diagnostics; errors via LEDs and system alarms.

  5. Green Manufacturing: Lead-free, RoHS-compliant for eco-friendly automation.

Compatibility

  • Controllers: Motoman MRC, XRC

  • Direct Replacements: DF9200676-B0, C0, D0

  • Pin-to-Pin Compatible: DF9200676-D0

  • Matching Boards:

    • Backplane: DF9200674-D0 / E0N

    • Servo: DF9200662-D0, DF9200664-D0N

    • Power: DF9200471-D1 / E0

Common Faults & Maintenance

Common Faults

  • No power: Blown fuse or faulty 24 V input.

  • Channel dead: Damaged optocoupler or terminal oxidation.

  • Bus error: Loose CN4 connector or backplane issue.

Maintenance

  • Use ESD protection when handling.

  • Keep connectors clean and free of dust/oxidation.

  • Verify 24 V DC stability before power-on.

  • Cut system power before removal/installation.

Applications

  • I/O control for Motoman MRC/XRC robot cabinets.

  • Integration of sensors, grippers, and material-handling peripherals.

  • New or upgraded systems requiring RoHS/lead-free components.

  • Industrial automation with environmental compliance requirements.