Yaskawa DF9200676-D0 I/O Control Board (JANCD-MRY01B-1)
Description
Model Definition
DF9200676: Base part number (I/O board series)
D0: Hardware revision (upgrade from C0; predecessor to D0N)
JANCD-MRY01B-1: Yaskawa official model name
D0N: RoHS‑compliant lead‑free version of D0
Specifications
Electrical
Input Voltage: 24 V DC ±10%
I/O Channels: 16 digital inputs / 16 digital outputs
Signal Level: 24 V DC / TTL compatible
Isolation: Optocoupler isolation per channel
Power Consumption: ~18 W
Features: Surge suppression, short‑circuit protection
Mechanical & Environmental
Dimensions: 220 × 150 × 25 mm
Weight: ~0.48 kg
Operating Temp: 0 °C to 55 °C
Storage Temp: −20 °C to 70 °C
Humidity: ≤80% RH (non‑condensing)
Protection: IP20 (cabinet use)
Interfaces
CN1: 24 V DC power input
CN2–CN3: 16‑in / 16‑out I/O terminals
CN4: System bus (to main backplane)
Onboard LEDs: PWR, RUN, ALM, CH status
Core Functions
Digital I/O Control: 16 inputs (sensors, switches) / 16 outputs (relays, actuators).
Signal Conditioning: Filtering, isolation, and level conversion for external signals.
Bus Communication: High‑speed data exchange with the main controller via backplane bus.
Fault Monitoring: Channel‑level diagnostics; reports errors via LEDs and system alarms.
System Expansion: Enables integration of grippers, conveyors, and other peripherals.
Compatibility
Controllers: Motoman MRC, XRC
Direct Replacements: DF9200676-B0, C0
Pin‑to‑Pin Compatible: DF9200676-D0N
Matching Boards:
Backplane: DF9200674-D0 / E0N
Servo: DF9200662-D0, DF9200664-D0N
Power: DF9200471-D1 / E0
Common Faults & Maintenance
Common Faults
No power: Blown fuse or faulty 24 V input.
Channel dead: Damaged optocoupler or terminal oxidation.
Bus error: Loose CN4 connector or backplane issue.
Maintenance
Use ESD protection when handling.
Keep connectors clean and free of dust/oxidation.
Verify 24 V DC stability before power‑on.
Cut system power before removal/installation.
Applications
I/O control for Motoman MRC/XRC robot cabinets.
Integration of sensors, grippers, and material‑handling peripherals.
Field replacement/upgrade for older B0/C0 boards.
Industrial automation requiring reliable, isolated digital I/O.
Get a Quote