ABB 1SAR700012R0005(C511.02-24)C511 Series Compact High-Precision Temperature Monitoring Relay
Description
Product Introduction
Model Interpretation
Technical Parameters
Supply voltage: 24 V AC/DC (±10 %)
Measuring range: −20 °C to +120 °C
Accuracy: ±2 °C; resolution: 0.1 °C
Sensor types: PT100, KTY83/84, NTC
Output: 1×NO relay contact, 250 V AC / 6 A max
Delay time: 0–30 s adjustable
Operating temperature: −20 °C to +60 °C; humidity 5–95 % RH, non-condensing
Protection class: IP65 front, IP20 rear
Dimensions: 75 × 30 × 25 mm; weight: approx. 0.2 kg
Approvals: CE, UL, CSA
Interface and Communication Configuration
Sensor input terminals (X1): for PT100, KTY, or NTC connection
Power terminals (A1/A2): 24 V AC/DC
Relay output (1NO): potential-free contact for alarm or shutdown
No built-in communication; for remote monitoring, use with external Modbus RTU/TCP modules
LED indicators: power ON, alarm, and fault status
Core Functions
Real-time temperature monitoring with high accuracy and resolution
Over-temperature and under-temperature alarm with adjustable thresholds
Selectable sensor types for flexible application
Adjustable delay time to avoid false alarms
Potential-free relay output for direct control of alarms, contactors, or valves
LED status indication for easy on-site diagnosis
Compact DIN-rail mounting for simple integration in control cabinets
Application Scenarios
Motor and generator winding temperature protection
Transformer, inverter, and power cabinet temperature monitoring
HVAC and building automation for duct/room temperature control
Food & beverage, pharmaceutical, and chemical process temperature supervision
Water treatment and pumping station equipment protection
Industrial machinery, packaging, and material handling equipment thermal monitoring
Operation and Maintenance Instructions
Mount vertically on standard DIN rail; ensure adequate ventilation
Wire sensors according to terminal diagram; avoid long parallel runs with power cables to reduce noise
Apply 24 V AC/DC power and check that the power LED is ON
Set temperature threshold and delay time via front potentiometers or DIP switches
Test alarm function by simulating over-temperature; verify relay actuation and LED indication
Periodically check wiring tightness and sensor condition; clean the front panel with a dry cloth only
Do not expose to corrosive gases, liquids, or direct moisture; keep ambient temperature within −20 °C to +60 °C
Replace the unit if LED indicates permanent fault or measurement drift exceeds tolerance