ABB 1KGT006700R0001 (560RTC01)

ABB 1KGT006700R0001, also known as 560RTC01, is a high-precision real-time clock (RTC) and synchronization module belonging to the ABB 560 series. It functions as a system time hub for RTU560/510, AC 500 PLC, and distributed I/O systems, providing accurate time references for event logging, process sequencing, and cross-module synchronization in time-critical industrial applications.

Description

Product Introduction

ABB 1KGT006700R0001, also known as 560RTC01, is a high-precision real-time clock (RTC) and synchronization module belonging to the ABB 560 series. It functions as a system time hub for RTU560/510, AC 500 PLC, and distributed I/O systems, providing accurate time references for event logging, process sequencing, and cross-module synchronization in time-critical industrial applications.

Model Explanation

  • 1KGT006700R0001: Full order part number

  • 560RTC01: Product series/model designation

  • Series: ABB 560-Series (Real-Time Clock & Synchronization)

  • Origin: Sweden

  • Weight: ~0.94 kg

Technical Parameters

  • Power Supply: 24V DC ±10% (via system backplane)

  • Time Synchronization: GPS + internal high-precision RTC

  • Time Accuracy:

    • GPS-locked: <1 μs

    • Free-running: <0.1 ppm (~9 ms/day)

  • Long-Term Drift: ±2 minutes/year (at 25°C)

  • Battery Backup: ≥10-year lifespan (supports off-power timekeeping)

  • Interfaces: RS-232, SPB I/O bus

  • Pulse Accuracy: 2 μs (first 20 min); 500 ns (after 20 min)

  • Operating Temp: -20°C ~ +70°C

  • Storage Temp: -40°C ~ +85°C

  • Humidity: 5%–95% RH (non-condensing)

  • Certifications: CE, UL, RoHS

Core Functions

  • High-Precision Timekeeping: Maintains accurate system time with ultra-low drift.

  • Event Timestamping: Tags process events with microsecond-level precision for audit and diagnostics.

  • System Synchronization: Aligns clocks across RTUs, PLCs, and I/O modules via SPB bus.

  • GPS Time Reference: Synchronizes to UTC via satellite for network-wide time consistency.

  • Redundant Time Source: Combines GPS and internal RTC for fail-safe operation.

  • Time Data Distribution: Broadcasts synchronized time to connected devices.

Application Scenarios

  • Power Utilities: Substation RTU560/510 synchronization, fault sequence recording, and grid event correlation.

  • Oil & Gas: Pipeline SCADA, compressor station sequencing, and wellhead data time alignment.

  • Water Treatment: Plant-wide process synchronization and event logging for compliance.

  • Smart Grids: Distributed energy management, meter data synchronization, and load balancing.

  • Industrial Automation: AC 500 PLC networks, distributed I/O, and multi-module coordination.

Usage & Maintenance

  1. Installation: Mount in RTU560/510 rack; connect backplane power and SPB bus.

  2. Configuration: Set GPS parameters, time zone, and synchronization priorities via ABB configuration software.

  3. Operation: Monitor GPS lock status and RTC health via front-panel LEDs.

  4. Maintenance:

    • Quarterly: Verify time accuracy and GPS signal strength.

    • Annual: Check battery health and backup timekeeping function.

    • Replacement: Use identical part number; re-sync system clock after replacement.