MOOG D661-4773 Electro‑Hydraulic Servo Valve
Description
Model Definition
D661 = Series (integrated electronics, 24 VDC, NG10)Moog Inc.Moog Inc.
4773 = Spool/sleeve assembly; rated flow 200 L/min @ ΔP=35 barMoog Inc.
Typical full config example: P60HDAM6NSF2‑A
P60 = High flow & high frequency response version
HDAM = Standard hydraulic layout, 24 VDC, ±10 V/±10 mA command, centered nullMoog Inc.
6 = 6+PE connector, IP65Moog Inc.Moog Inc.
NSF2 = NBR seals, wide temperature range, LVDT feedback 4–20 mAMoog Inc.
A = Standard ServoJet® pilot stageMoog Inc.
Technical Specifications
Hydraulic Parameters
Rated flow: 200 L/min (ΔP=35 bar)Moog Inc.
Max working pressure: 350 bar (P/A/B); 210 bar (internal drain T) / 350 bar (external drain T)Moog Inc.
Step response: 8–14 ms (0→100%, 210 bar)Moog Inc.
Hysteresis: <0.2%Moog Inc.
Resolution: <0.1%Moog Inc.
Null drift: <1.5% (ΔT=55 K)Moog Inc.
Null leakage: <25 mL/minMoog Inc.
Fluid cleanliness: NAS 1638 Class 6 / ISO 4406 18/15Moog Inc.
Electrical Parameters
Power supply: 24 VDC (18–32 VDC)Moog Inc.
Control signal: ±10 V (differential) or ±10 mAMoog Inc.
Feedback signal: 4–20 mA (LVDT spool position)Moog Inc.
Connector: 6+PE, IP65Moog Inc.Moog Inc.
Current draw: ≤750 mAMoog Inc.
Physical & Environmental
Operating temperature: −40 ℃ to +85 ℃Moog Inc.
Weight: approx. 10.2 kg
Interface & Communication Configuration
Hydraulic interface: P/A/B/T, ISO 4401‑05 (NG10)Moog Inc.
Electrical interface:
Power: 24 VDC, GND, PEMoog Inc.
Command: ±10 V / ±10 mAMoog Inc.
Feedback: 4–20 mA (spool position)Moog Inc.
Status: Fault alarm output
Core Functions
ServoJet® pilot stage: Superior contamination resistance, low null drift, extended service lifeMoog Inc.
Integrated high‑response amplifier: Built‑in PID, dead‑zone compensation, overload protectionMoog Inc.
LVDT closed‑loop feedback: High linearity and precision across full strokeMoog Inc.
Fail‑Safe centering: Spool returns to neutral on power loss
High‑flow dynamics: Optimized for 200 L/min with fast response for high‑speed applicationsMoog Inc.
Application Scenarios
Metallurgy: High‑flow AGC roll gap control, tension control for heavy plate mills
Test equipment: High‑force dynamic material testers, high‑frequency vibration tables
Industrial automation: Large CNC machine tools, high‑speed hydraulic presses, heavy‑duty injection molding machines
Energy & heavy industry: Wind turbine pitch control, shield machine main control, marine hydraulic systems
Usage & Maintenance
Installation: Horizontal/vertical mounting; avoid severe vibrationMoog Inc.
Fluid: ISO VG46 mineral oil; maintain cleanliness per NAS 1638 Class 6Moog Inc.
Commissioning: Apply 24 VDC power; connect ±10 V/±10 mA command; calibrate zero and gain via 4–20 mA feedbackMoog Inc.
Maintenance: Inspect fluid contamination regularly; calibrate zero/gain every 6 months; avoid long idle periods at high pressureMoog Inc.
Get a Quote