MOOG D661-4652G15JOAA6VSX2HA Electro-Hydraulic Servo Valve
Description
Model Definition
D661: Series with integrated electronics, 24 VDC power supply and NG10 installation dimension
4652: Spool and sleeve assembly, rated flow 75 L/min at 35 bar pressure drop
G15JOAA6VSX2HA: Full configuration code
G: Standard spool equipped with ServoJet® pilot stage
15: Frequency response class with bandwidth up to 60 Hz
J: 24 VDC power supply, compatible with ±10 V or ±10 mA analog control signal
O: Centered null position with fail-safe function
AA: Standard hydraulic and electrical base configuration
6: 6+PE electrical connector with IP65 protection grade
VS: Special sealing material suitable for wide temperature range
X2HA: LVDT spool position feedback with 4-20 mA output and standard performance parameters
Technical Specifications
Hydraulic Parameters
Rated flow: 75 L/min (ΔP=35 bar)
Maximum operating pressure: 350 bar for port P, A and B; 210 bar for internal drain port T, 350 bar for external drain port T
Step response: 6.5-10 ms (0 to 100% stroke under 210 bar)
Hysteresis: Less than 0.2%
Resolution: Less than 0.1%
Temperature drift: Less than 1.5% (ΔT=55 K)
Null leakage: Less than 10 mL/min
Recommended fluid cleanliness: NAS 1638 Class 6 or ISO 4406 18/15
Electrical Parameters
Power supply: 24 VDC (18-32 VDC)
Control signal: ±10 V or ±10 mA
Feedback signal: 4-20 mA from LVDT spool position sensor
Electrical connector: 6+PE, IP65
Working current: Maximum 350 mA
Physical & Environmental Parameters
Operating temperature: -40 ℃ to +85 ℃
Weight: Approximately 8.0 kg
Interface & Communication Configuration
Hydraulic interface: Four ports P, A, B, T complying with ISO 4401-05 standard
Electrical interface: Terminals for 24 VDC power, GND and PE; terminals for ±10 V/±10 mA command signal; 4-20 mA position feedback terminals and fault status output terminals
Core Functions
ServoJet® pilot stage delivers strong anti-pollution capability, low null drift and long service life
Integrated closed-loop amplifier supports PID regulation, dead zone compensation and overload protection
LVDT position feedback guarantees excellent linearity and positioning accuracy throughout the full stroke
Fail-safe design enables the spool to return to neutral position automatically when power is disconnected
Stable 60 Hz bandwidth satisfies the dynamic control demands of general industrial equipment
Application Scenarios
Metallurgical industry: Large flow AGC roll gap control and tension control systems
Testing equipment: Dynamic material testing machines, fatigue test benches and medium frequency vibration tables
Industrial automation: Large precision machine tools, high-speed injection molding machines and hydraulic forming equipment
Energy and heavy industry: Wind turbine pitch control, main control of shield machines and marine hydraulic systems
Usage & Maintenance
Mount the valve horizontally or vertically and keep it away from severe vibration
Adopt qualified hydraulic oil and maintain fluid cleanliness above NAS 1638 Class 6
Supply 24 VDC power and access ±10 V or ±10 mA command signal during commissioning, then complete zero adjustment and gain calibration according to 4-20 mA feedback signal
Check hydraulic fluid contamination regularly. Calibrate null position and gain every six months. Avoid long-term high-pressure standby without control command.
Get a Quote